Alaris IVAC Signature Gold Series
The Alaris/IVAC Signature Gold Series Infusion System is a versatile infusion solution that comes with two main models – the Model 7100 (single-channel) and Model 7200 (dual-channel) Volumetric Infusion Pumps – plus the AccuSlide Flow Regulator administration sets. These pumps are designed to deliver a wide range of IV fluids safely and accurately, whether you’re using them for general IV fluids, TPN, antibiotics, lipids, blood products, or even anesthesia and cardiovascular drugs.
The single-channel pump offers a full range of features in a small, easy-to-use linear peristaltic design, while the dual-channel version gives you two independent infusion pumps in one unit. One of the cool things about this system is its flexibility – it works with a variety of fluid container types and a wide range of infusion rates. The system also makes use of the unique, patented AccuSlide Flow Regulator, which not only controls the flow accurately during gravity administration but also minimizes the risk of accidental free flow when the administration set is removed from the pump.
Key Features and Benefits:
- Versatile Pump Options:
- Single-channel (Model 7100) for a compact, easy-to-use solution
- Dual-channel (Model 7200) offers two independent infusion pumps in one unit
- Wide Fluid Compatibility: Can be used with IV fluids, electrolytes, TPN, antibiotics, lipids, blood products, irrigation solutions, epidurals, anesthesia, enteral solutions, and cardiovascular drugs.
- AccuSlide Flow Regulator:
- Integral flow control minimizes accidental free flow
- Provides accurate rate control during gravity administration
- Flexible Infusion Rates:
- Offers flow rate adjustments in fine increments (as low as 0.1 mL/hr) up to nearly 1000 mL/hr
- Separate settings for primary and secondary (piggyback) infusions
- User-Friendly Design:
- Easy-to-read controls and clear settings help simplify operations
- Rechargeable nickel-cadmium internal battery for portable use
Specifications:
Alaris 7130
- Flow Rate Range:
- Primary: 0.1 to 999.9 mL/hr in 0.1 mL/hr increments
- Secondary: 0.1 – 270 mL/hr
- Volume to be Infused:
- Primary: 0.1 to 9999.9 mL in 0.1 mL increments
- Secondary: 0.1 to 999.9 mL in 0.1 mL increments
- KVO Flow Rate: 0.1 to 20.0 mL/hr in 0.1 mL/hr increments
- Internal Battery: Rechargeable nickel-cadmium, with a capacity of 4 hours at 100 mL/hr
- Power Requirements: 100-120 V, 0.5A, 50-60 Hz, 3-wire ground system (max 40 watts)
- Dimensions: 7.6” wide, 8.6” high, 5.0” deep
- Weight: 6.6 lbs
Alaris 7230
- Flow Rate Range:
- Primary: 0.1 to 999.9 mL/hr in 0.1 mL/hr increments
- Secondary: 0.1 – 270 mL/hr
- Volume to be Infused:
- Primary: 0.1 to 9999.9 mL in 0.1 mL increments
- Secondary: 0.1 to 999.9 mL in 0.1 mL/hr increments
- KVO Flow Rate: 0.1 to 20.0 mL/hr in 0.1 mL/hr increments
- Internal Battery: Rechargeable nickel-cadmium, with a capacity of 3 hours at 100 mL/hr
- Power Requirements: 100-120 V, 0.5A, 50-60 Hz, 3-wire ground system (max 40 watts)
- Dimensions: 10.7” wide, 8.6” high, 5.0” deep
- Weight: 8.4 lbs