B Braun Outlook 100ES
The B Braun Outlook 100ES Safety Infusion Pump is designed with patient safety and ease-of-use in mind. It comes equipped with a color-coded keypad and audible key clicks, which makes programming and operation really straightforward. The pump provides a comprehensive “at-a-glance” view of infusion status on its large color display, so you can quickly verify settings and monitor progress.
This system is built to help prevent IV medication errors. Its extensive, customizable DoseGuard™ drug library lets you tailor the pump to match your clinical practice, reducing the risk of dosing mistakes. Each pump even has its own “brain” to help prevent channel confusion and avoid catastrophic pump failures. Plus, the non-numeric KeyGuard™ keypad with simple arrows helps cut down on manual programming errors—especially those pesky issues with zeros and decimals.
Other notable features include an air trapping cassette that catches up to 3 mL of air (helping to reduce nuisance air-in-line alarms), a proven delivery mechanism for reliable and accurate operation, and a real-time display of dose and limit values during infusion that enhances titration safety. The active alphabetic matrix makes drug selection quick and easy, and the system supports both Loading Dose and On Demand Bolus configurations for all DoseGuard™ drugs.
Specifications:
-
Dimensions:
- Width: 30.5 cm (12 in)
- Height: 11.4 cm (4.5 in)
- Depth: 22.2 cm (8.75 in)
- Weight: 5 kg (11 lbs)
-
Power:
- Input: 120 VAC, 3A, 60 Hz
- Grounding Resistance: Meets or exceeds UL Standard 2601-1
- Leakage Current: Meets or exceeds UL Standard 2601-1
-
General:
- Mechanism: Positive Pressure Displacement Reservoir
- UL Certified: Yes (meets or exceeds UL Standard 2601-1 and has an IPX1 drip rating)
- Battery: 12V NiMH
- Battery Operating Time: Approximately 7 hours at 25 mL/hr
-
Infusion Parameters:
- Rate Range: 0.1 to 999.9 mL/hr in 0.1 mL/hr increments
- Micro Mode: 0.1 to 99.9 mL/hr in 0.1 mL/hr increments
- Volume to be Delivered: 0.1 to 9,999.9 mL in 0.1 mL increments
- Occlusion Pressure: Adjustable settings at 75, 100, 200, 300, 400, 500, and 750 mmHg
- KVO Rate: 3 mL/hr or the selected rate, whichever is lower
- Volumetric Accuracy: ± 5%
-
Alarms:
Includes Air-in-line, Hold Time Exceeded, Low Battery Warning, Plug In Alarm, DoseGuard™ Alert, RateGuard™ Alert, Downstream Occlusion, Check Set, Bag Empty, Upstream Occlusion, and System Error alarms -
Tubing:
Compatible with Horizon® Pump Sets -
Modes/Features:
- DOSE Mode with DoseGuard™ Drug Library
- Primary and Piggyback Modes with RateGuard™ Solution Library
- Loading Dose and On-demand Bolus Modes
- Profile Mode, Program Mode, Set Time and Volume, Schedule Next Run
- Micro Mode, q(x) Mode, Epidural Mode
Reviews