CardioQuip MCH-1000(m) Heater/Cooler System
The CardioQuip MCH-1000(m) is a compact and efficient heater/cooler system tailored for procedures that demand precise thermal regulation. Its smaller footprint makes it ideal for environments with limited space, while still delivering reliable performance for critical care and surgical applications. Featuring an intuitive touchscreen interface and self-priming technology, the MCH-1000(m) simplifies operation and enhances workflow by automatically removing air from tubing lines. With accurate temperature control from 0°C to 42°C (±0.5°C) and flexible connection options via quick-connect fittings, this system is designed to integrate seamlessly into diverse clinical setups.
Key Features
- Compact Design:
- Space-efficient unit ideal for settings with limited room without compromising performance.
- Accurate Temperature Control:
- Maintains temperatures from 0°C to 42°C with a precision of ±0.5°C and adjustable in 0.1°C increments.
- User-Friendly Interface:
- Intuitive touchscreen facilitates easy temperature adjustments and system monitoring.
- Self-Priming Technology:
- Automatically removes air from tubing lines, reducing manual effort and enhancing safety.
- Flexible Connections:
- Equipped with quick-connect, no-spill, two-way shutoff fittings and compatible with various hose kits for seamless integration.
- Versatile and Modular:
- Designed for diverse applications with optional modules like the MCH-11TEC Thermoelectric Cooling Lid Module for enhanced cooling performance.
Detailed Specifications
Dimensions & Weight
- Dimensions:
- Height: 16 in (41 cm)
- Width: 9 in (23 cm)
- Depth: 19 in (48 cm)
- Weight:
- Empty: 45 lb (20 kg)
- Full: 65 lb (29 kg)
- Maximum: 76 lb (34 kg)
General Features
- Water Capacity:
- Minimum: 1 gal (3.8 L)
- Maximum: 2.5 gal (9.5 L)
- Cooling Medium:
- Uses ice; optionally compatible with a Thermo-Electric Cooling Module.
- Water Path:
- Single path design.
- Maximum Flow Rate:
- High: 20 L/min (5.3 GPM)
- Low: 14 L/min (3.7 GPM)
- Maximum Pressure:
- 83 kPa / 12 psi (closed loop, blocked flow)
- Water Connections:
- Quick-connect, no-spill, two-way shutoff fittings with hose kit included.
Temperature Control & Power
- Temperature Control Range:
- 0°C to 42°C with an accuracy of ±0.5°C, adjustable in 0.1°C increments.
- Power Consumption:
- Maximum Peak: 1900 W; Typical: <1740 W
Optional MCH-11TEC Thermoelectric Cooling Lid Module
- Dimensions:
- 14.5 in x 9 in x 8.5 in (36.8 x 22.9 x 21.6 cm)
- Weight:
- 8.65 lb (3.9 kg)
- Induced Airflow:
- <3.5 ft³/min
- Power Consumption:
- Maximum Peak: 100 W; Typical: <85 W