Mizuho OSI Hana Table
The Mizuho OSI Hana Table is a state-of-the-art fracture table designed to optimize the anterior approach to total hip arthroplasty (AATHA). With its unique patient positioning capabilities, the Hana Table enables surgeons to perform hip replacements through a single incision without detaching muscles from the pelvis or femur. It features safe hyperextension, adduction, and external rotation of the leg, thanks to the patented femoral lift and support system that enhances femoral exposure for improved component placement. The split design of the lower half allows each leg to be positioned independently without special external support, while special boots secure the legs comfortably once positioned. Since its introduction in 2005, the Hana Table has successfully supported thousands of hip procedures.
Key Features
- Optimized for Anterior Hip Surgery:
- Enables single-incision total hip arthroplasty with safe hyperextension, adduction, and external rotation.
- Advanced Femoral Exposure:
- Patented femoral lift and support system enhances exposure for precise component placement.
- Independent Leg Positioning:
- Split design of the lower half allows independent positioning of each leg without additional support.
- Robust & Versatile Construction:
- Carbon fiber tabletop for strength and radiolucency.
- Stainless steel base with lightweight spars.
- User-Friendly Controls:
- Auxiliary control module with replaceable control unit.
- Physician-controlled foot pedal and manual floor locks for secure positioning.
- Power Flexibility:
- Operates on AC or battery power.
- Spherical Spatial Positioning System (SSPS):
- Enhances accuracy and ease of positioning for a wide range of procedures.
Detailed Specifications
Table Dimensions & Capacity
- Table Top Length:
- 48.5 in (123 cm)
- Overall Table Length with Spars:
- 124 in (315 cm)
- Table Top Width:
- 21.5 in (55 cm); narrows to 10 in (25 cm) near the perineal post.
- Table Height Range:
- 30–50 in (76–127 cm)
- Patient Weight Capacity:
- Up to 450 lbs (205 kg)
Power Requirements
- Voltage Options:
- 100V (50/60 Hz), 120V (60 Hz), or 220/230V (50/60 Hz)
Motion & Positioning
- Trendelenburg/Reverse Trendelenburg:
- 12°
- Lateral Tilt:
- 12°
- Leg Spar Articulation:
- 28° upward, 35° downward, 20° adduction, 45° abduction
- Positioning Capabilities:
- Supports both supine and lateral patient positions
Additional Features
- Accessory Side Rails:
- Provide additional mounting options for necessary accessories.
- Spherical Spatial Positioning System (SSPS):
- Ensures accurate and intuitive spatial positioning.
- Control Options:
- Includes an auxiliary control module and physician-controlled foot pedal.
- Mobility:
- Designed with manual floor locks for stable positioning.
Reviews